Omron frequency converter 60hz 50hz vfd 3G3MX2-A4075-ZV1

Series#: Omron

Product Details

  • Product Details
  • Omron frequency converter 60hz 50hz vfd 3G3MX2-A4075-ZV1
  • We are First Class Omron VFD Frequency Inverter dealer and Omron VFD Frequency Inverter distributor in China.
  • We can Supply Omron automation parts,such as Omron PLC,Omron Servo Motor,Omron HMI,Omron VFD and Omron Relay and Omron Sensor and ect.
  • 100% Original and new,In stock by Omron Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs

Specification

Function nameSpecifications
Enclosure   ratings *1Open   type (IP20)
Control methodPhase-to-phase   sinusoidal modulation PWM
Output   frequency range *20.10   to 400 Hz (or 580 Hz in the high-frequency mode; restrictions apply)
Frequency precision *3Digital   command: ±0.01% of the max. frequency, Analog command: ±0.2% of the max.   frequency (25±10°C)
Frequency   setting resolutionDigital   setting: 0.01 Hz, Analog setting: One-thousandth of the maximum frequency
Voltage/Frequency characteristicsV/f   characteristics (constant/reduced torque)Sensorless vector control, V/f   control with speed feedback
Overload   current ratingHeavy   load rating (CT): 150%/60 s Light load rating (VT): 120%/60 s
Instantaneous overcurrent protection200%   of the value of heavy load rating (CT)
Acceleration/Deceleration   time0.01   to 3600 s (linear/curve selection), acceleration/deceleration 2 setting   available
Carrier frequency adjustment range2   to 15 kHz (with derating)
Starting   torque200%/0.5   Hz (sensorless vector control)
External DC injection brakingStarts   at a frequency lower than that in deceleration via the STOP command, at a   value set lower than that during operation, or via an external input. (Level   and time settable).
 Protective   functionsOvercurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground fault overcur-   rent at power-on status, rush current prevention circuit, overload limit,   incoming overvoltage, exter- nal trip, memory error, CPU error, USP error, communication error, overvoltage suppression during   deceleration, protection upon momentary power outage, emergency   cutoff, etc.
Frequency settingsDigital   OperatorExternal analog input signal: 0 to 10 VDC/4 to 20 mA, Modbus   communication (Modbus-RTU)
RUN/STOP   commandDigital   OperatorExternal digital input signal (3-wire input supported), Modbus   communication (Modbus-RTU)
Multi-function input *47   points (Functions can be selected from among 68)
Analog   input *52   points (Voltage FV terminal: 10 bits/0 to 10 V, Current FI terminal: 10   bits/4 to 20 mA)
Pulse input1   point (RP terminal: 32 kHz max., 5 to 24 VDC)
Multi-function   output *42   points (P1 and P2, Functions can be selected from among 47)
Relay output *41   point (SPDT contact (MC, MA, MB), Functions can be selected from among 47)
Analog   output (Frequency monitor)*61   point (AM terminal: Voltage 10 bits/0 to 10 V) (Frequency, current   selectable)
Pulse output1   point (MP terminal: 32 kHz max., 0 to 10 V)
RS-422RJ45   connector (for Digital Operator)
RS-485Control   circuit terminal block, Modbus communication (Modbus-RTU)
USBUSB1.1,   mini-B connector
  Other functionsAVR   function, V/f characteristics switching, upper/lower limit, 16-step speeds,   starting frequency adjustment, jogging operation, carrier frequency   adjustment, PID control, frequency jump, analog gain/bias adjustment, S shape   acceleration/deceleration, electronic thermal characteristics, level   adjustment, restart function, torque boost function, fault monitor, soft lock   function, frequency conversion display, USP function, motor 2 control   function, UP/DWN, overcurrent control function, etc.
Ambient   operating temperature *7-10   to 50°C (However, derating is required).
Ambient storage temperature-20°C   to 65°C
Ambient   operating humidity20%   to 90% RH (with no condensation)
Vibration resistance5.9   m/s2 (0.6G), 10 to 55 Hz
Application   environmentAt   a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
EtherCAT Communication Unit3G3AX-MX2-ECT
CompoNet   Communication Unit3G3AX-MX2-CRT-E
DeviceNet Communication Unit3G3AX-MX2-DRT-E


Unmatched Customer Service

s03-icon1

After Hours Shipping

s03-icon1

Real Time Order Tracking

s03-icon1

Flexible Delivery Options

s03-icon1

Intact Technical Supports

What Does Our Clients Say

Mitsubishi MR-J4 Servo motor

Laura Navas

Great product, great service and we saved money. Excellent !

2019/12/01

Hongfa Relay enquiry

Daniel Frey

The supplier have a professional team to deal my orders,free technique support,fast shipping,warmly service.They also helped me to built the FANUC and Mitsubishi test bench,good partner,looking forward more cooperation in the future.

2020/01/01

Fanuc servo motor repair from Canada

Clayton Steytler

thanks for you support, your engineers solved my problem, thanks also, and want to send you parts for repair.fast shipping.

2020/02/08

Keyence sensor

EQDR SALES

Original and fast shipping,will order again!good supplier!

2020/02/22

Hongfa Relay&Omron relay

Roly Franco

good quality,well done.works well.

2020/02/28

Board A20B-1002-0710 FANUC

Ollie Santos

Great Seller, item arrive in good order, and work fine, thanks.

2020/04/15

fanuc amplifier A06B-6114/7-H206

Amanda

ship quickly and tested drive well, good supplier

2020/04/18

Elevate Your Business Operations With Hanyu intelligent's Industrial Automation Products

  • Best-in-class sourcing
  • MOQ starts from 1 piece
UP